Between 1920 and 1960, tens of thousands of houses were built in the United States. Almost all of them had two prong outlets. Many of them still do. While the majority of Indiana's houses were built in the 1990s, there are more than 8,600 currently for sale built between 1920 and 1960 in the Hoosier state. Many more off the market. If you live in a house with two prong outlets, you might want to consider an upgrade. You are at risk for more than inconvenience when you try and plug in your 21st century TV into one of these outlets.

High-Speed Steel T-Slot End Mills Use these end mills for general purpose work in most material, such as aluminum, brass, bronze, iron, and steel. They're often used to create slots in machine. Truth Hardware and Amesbury merged in 2013. By joining forces, AmesburyTruth became an industry-leading organization offering an extensive product line and considerable global resources. AmesburyTruth is now perfectly positioned to provide customers even greater opportunity to take advantage of engineered solutions. I didnt know either so i had to research. 20A Outlets: Some electrical outlets have a 'T' shaped slot on the neutral instead of just a vertical slot. These outlets are rated for 20A, and can receive special plugs (with a sideways neutral prong) for appliances which draw more than 15A. 20-amp receptacles have a horizontal slot branching off one of the vertical slots. Appliances, such as microwaves, often have 20-amp plugs and must be plugged into a 20-amp outlet. Electrical plugs designated as 20-amp will not fit into 15-amp outlets.

Risks Associated With Two Prong Outlets

There are two risks associated with two prong outlets: electrocution and power surges. Both of these issues have to do with the fact that the wiring in two prong outlets isn't grounded. In outlets built since 1962, U.S. electrical code has required all outlets be constructed with a ground wire. This ground wire protects electronics and people from electrical surges and faults by providing a pathway for extra energy to escape the house's circuitry. When a fault or surge occurs with grounding, the energy travels through the ground wire to the electrical panel. There, it will trip the circuit breaker or blow a fuse, thereby shutting down the circuit before damage (hopefully) occurs. The energy then continues through the ground wire into the earth below the structure, where it dissipates harmlessly.

Without grounding, it's also impossible to protect your electronics and appliances with surge protectors. Surge protectors work only if they are can connect to a ground wire. Vpa sports overview. Without this wire, they offer no better protection for electronic devices than do multiprong outlets.

Two Prong Outlets are Not Up to Code

Upgrading your home's electrical system can cost between 5 and 15 percent of your home's value — a price tag many people cannot afford. With this in mind, regulators determined that homeowners with two prong outlets need not upgrade them. However, that doesn't mean they're the safest option.

For more than 50 years, code has required all new construction have grounded, three prong outlets. More recently, U.S. electrical code has required that not only outlets be grounded but that outlets in areas with water present have a GFCI. A GFCI, short for ground-fault circuit interrupter, protects people from electrical shock by cutting off the circuit if a short circuit occurs. (A short circuit is when energy is directed out of the regular circuit pathway through a path with little or no resistance.) If that short circuit occurs because a person is being electrocuted, a GFCI can save their life.

No such protection is available with a two prong outlet.

Two Prong Outlets Suggest Other Problems

Two prong outlets also raise flags about other electrical issues that may be present. Homes built before 1965 were built with 30- or 60-amp fuse panels. While 60-amp fuse panels were made with at least one 240-volt wire for larger appliances, 30-amp fuse panels only provide 120-volt wiring, and they are inadequate for modern household electrical needs.

60-amp fuse boxes are problematic because they, too, cannot handle well modern requirements upon electrical systems. In comparison, newly constructed homes today are built with 200-amp circuit breakers (the service panels that replaced fuse boxes).

When there is too much energy running through a wire, the wire heats up, putting the house at risk for fire. Too much energy (electricity) will also blow fuses. You will have to constantly replace if your fuse box's amperage rating doesn't meet your needs.

Another problem to be on guard for when two prong outlets are present is the lack of grounding in outlets that have three prongs. If a house has both two and three prong outlets, it means that the three prong outlets were installed for convenience and that they're not actually grounded. It could also means that only part of your house's electrical system is grounded.

You will want to test your outlets to find out whether they are grounded or not. If the three prong outlets are not grounded, regulations require that you label them with the words 'No Equipment Ground.'

Four Ways to Upgrade 2 Prong Outlets

To upgrade your two prong outlets, you cannot simply add a three prong outlet. While this will solve the convenience issue, it will not solve the safety issue.

If you truly want to address your two prong outlets and make them safer, you have four options.

Option 1: Rewire Your Outlets

Your first, and best, option is to hire an electrician to rewire your house's outlets and its electrical panel. Do casinos cheat. If the expense is a concern, consider having your electrician rewire select outlets into which you will plug larger or more sensitive electronic devices, such as a computer or game counsel.

Note that this is not a project you can do yourself. Only a certified electrician has the expertise necessary to run a ground wire from the outlet to the service panel and then properly ground it.

Option 2: Ground Three Prong Outlets with the Metal Housing Box

T Slot Outlet

Many two prong outlets were installed in metal boxes. While the circuitry itself wasn't grounded, these individual boxes oftentimes were. If your house has two prong outlets with metal boxes, it is possible you can ground your outlets without overhauling the wiring.

T Slot Outlet Warehouse

To find out whether the metal housing is grounded, purchase a circuit tester. Insert one of the tester's prongs into the hot slot (the shorter slot in the outlet). Put the other prong onto a screw holding the cover plate. If the tester lights up, it means the metal box is grounded.

If the box is grounded, you can install a three prong outlet and ground it by attaching it to the armored, or BX, cable in the back of the box.

Option 3: Install a GFCI at the Outlet

T Slot Outlet Mall

The third option to upgrade a two prong outlet is to replace it with a GFCI. While a GFCI will not protect your electronics from power surges, it will protect you from electrocution and short circuits. If you replace your ungrounded, two prong outlet with a GFCI, you must label it with 'No Equipment Ground.'

Letting Go Quotes Quotes tagged as 'letting-go' Showing 1-30 of 1,117 'The truth is, unless you let go, unless you forgive yourself, unless you forgive the situation, unless you realize that the situation is over, you cannot move forward.' ― Steve Maraboli, Unapologetically You: Reflections on Life and the Human Experience. Letting go helps us to to live in a more peaceful state of mind and helps restore our balance. It allows others to be responsible for themselves and for us to take our hands off situations that do not belong to us. This frees us from unnecessary stress. Famous quotes about letting go. Following are 20 quotes that may inspire letting go or letting be, whatever you prefer! 'By letting it go it all gets done. The world is won by those who let it go. But when you try and try, the world is beyond the winning.' Lao Tzu. The Best Quotes about Letting Go The truth is, unless you let go, unless you forgive yourself, unless you forgive the situation, unless you realize that the situation is over, you cannot move forward.

Option 4: Install a GFCI at the Circuit Breaker

It's also possible to replace your two prong receptacles with three prong ones and add a GFCI circuit breaker at the service panel. Doing this will likewise protect you from electrocution. If you do this, you will have to label outlets with 'GFCI Protected, No Equipment Ground.'

T Slot Outlet Columbus Ohio

Whatever you decide to do, we recommend having a certified electrician complete your electrical work. Safety is always a concern when working with electricity, and an expert will best take care of your home.